The CEI 11-27 standard is the key reference for safety when working on electrical systems, in compliance with Italian Legislative Decree 81/2008. This article examines in detail the key roles set out in the standard, their responsibilities and the latest changes introduced by the fifth edition. Find out how to ensure safety and the proper management of activities on electrical systems.

CEI 11 27 standard: roles involved, training and responsibilities

Contents:

  • 4.1 Training and requirements
  • 4.2 Changes in the CEI 11-27 standard concerning PES, PAV, PEI and PEC
  • 5.1 URI: installation-responsible unit
  • 5.2 RI: installation manager
  • 5.3 URL: work-responsible unit
  • 5.4 PL: work supervisor
  • 5.5 Changes to points 3.2.2 (RI) TITLE; 3.2.3 (URL) DEFINITION; 3.2.4 (PL) TITLE AND DEFINITION.

1. What is the CEI 11-27 standard?

The CEI 11-27 standard covers work on electrical systems and is the technical reference standard for all work activities on electrical systems, which are governed by Italian Legislative Decree 81/2008.

This CEI standard applies to operations and work activities on electrical systems, related activities and operations carried out near them.

It applies to all operations, both direct and indirect, and covers electrical systems of any type and voltage level, whether fixed, mobile, permanent or temporary, intended for the production, transmission, transformation, distribution and use of electrical energy.

The CEI 11-27 standard sets out safety requirements for the activities on electrical systems described above and, in particular, applies to work and operating procedures during work and maintenance.

The standard applies to all electrical work and also to non-electrical work, such as construction work carried out near electrical systems, overhead power lines or uninsulated or inadequately insulated underground cables. (under Legislative Decree 81/08).

* Source: certifico.com

2. What changes did the fifth edition introduce?

The CEI 11-27 standard replaces the previous edition of 2014.

Let us look at the process that led to the definition of this standard:

Today we will focus on the changes made to the key roles identified by the CEI 11-27 standard for the correct management and planning of work on live systems.

The changes discussed here are not merely formal but also operational, improving the organisation and management of activities on electrical systems.

3. Key roles identified by the CEI 11-27 standard

The previous editions of the CEI 11-27 standard already required, to improve business organisation and control electrical risk, the creation of a network of people enabling operational tasks to be divided and, consequently, a better system of controls for managing electrical risk and ensuring safety during electrical work.

In particular, the PES, PAV and PEI roles are identified.

While PES, PEI and PAV identify the workers who carry out electrical work operationally, the CEI 11-27 standard requires additional roles for the correct management and planning of electrical work. These are:

  • URI (installation-responsible unit)
  • RI (installation manager during electrical work)
  • URL (work-responsible unit)
  • PL (supervisor for electrical work)

We will first clarify the PES, PAV and PEI roles, and then examine the changes concerning the definition of the installation-responsible unit (URI), the installation manager during electrical work (RI), the work-responsible unit (URL) and the supervisor for electrical work (PL).

4. PES, PAV and PEI roles in electrical work

Italian Legislative Decree 81/08 establishes that the various types of electrical work must be carried out by qualified personnel informed about the dangers arising from electrical risk and possessing all the requirements needed to work on live systems.

The CEI 11-27 standard, together with the provisions of the Italian consolidated workplace-safety legislation, establishes that these professional roles are assigned the PES, PAV and PEI qualifications according to their level of competence. Let us examine their duties and differences.

First, let us define these roles:

  • PES: an expert person who carries out electrical work, with technical and theoretical knowledge enabling them to analyse and assess electrical risks. They may carry out dead work and work near live parts.
  • PAV: an informed person, meaning someone informed about electrical risks by a PES. They may work dead and near live parts under supervision.
  • PEI: a person qualified for live working, meaning someone authorised to carry out electrical work on live systems. They may perform all types of electrical work.
  • PEC: an ordinary person: someone neither expert nor informed in the field of electrical activities.

4.1 Training and requirements for PES, PAV and PEI

The CEI 11-27 standard establishes a training programme to prepare electrical workers for their duties, ensuring that they acquire the necessary theoretical and practical skills.

The competence levels are defined as follows:

  • Level 1A: basic theoretical knowledge
  • Level 1B: operational skills
  • Level 2A: theoretical knowledge for live working
  • Level 2B: practical skills for live working

**
Appointment requirements**

PES and PAV: written appointment by the employer, based on instruction, experience and personal characteristics.

PEI: appointment by the employer, with checks of physical and psychological fitness, professional CV and training.

4.2 Changes in the CEI 11-27 standard concerning PES, PAV and PEI

The only truly important operational point in the latest edition of the CEI 11-27 standard compared with the previous version of 2014 concerning these roles is the following:

The possibility for an ordinary person (PEC), who is neither PES nor PAV, to take measurements—that is, to use measuring instruments on live systems—has been removed. If a PEC takes measurements in the presence of live voltage, this is for training purposes and only under the direct supervision of a PES or PAV.

A PEC may take measurements in the presence of electrical risk only when supervised by a PES or PAV.

*Source: AIAS Piemonte

Having clarified the roles described above, let us look at the additional roles identified by the CEI 11-27 standard for the correct management and planning of electrical work.

5. CEI 11-27 standard: URI, RI, URL and PL

Who are these people and what roles do they perform?

5.1 URI: installation-responsible unit

The unit responsible for the overall management of the installation, ensuring safety during normal operation. This role may be performed by the owner, the user or a designated person.

5.2 RI: installation manager

The person appointed to ensure installation safety during work. They are responsible for planning and coordinating with the other people involved.

5.3 URL: work-responsible unit

The unit or person responsible for carrying out the work. They are responsible for preparing and organising the work, checking resource availability and operator training.

5.4 PL: work supervisor

The person responsible for the operational coordination of the work, with extensive experience of electrical systems. They must be recognised as a PES.

5.5 Changes to points 3.2.2 (RI) TITLE; 3.2.3 (URL) DEFINITION; 3.2.4 (PL) TITLE AND DEFINITION.

Changes to point 3.2.2 (RI)_installation manager: Person appointed to operate the electrical installation during the work activity).

This clearly explains the scope of this role. The installation manager (RI), together with the work supervisor (PL), are the two people whose presence is considered fundamental and whose absence is subject to penalties, since Italian Legislative Decree 81 explicitly refers to applying regulatory principles to define compliance, and therefore adherence to good workmanship, when carrying out electrical work.

The installation manager is responsible for making the installation safe and operating the part of the installation not involved in the electrical work—for example, during dead working—but within a time and space context closely linked to the performance of the electrical work.

The distinction is therefore clarified between the owner or user, whose role is that of URI and who is responsible for operating the installation under ordinary conditions, and the installation manager, who is responsible for operating the installation and making it safe for the performance of electrical work while that work is being carried out.

This doubt has been resolved!

Another change concerning the installation manager (RI), mentioned in point 4.12 of the standard, establishes the duties to be performed by this role. Some of these duties may be delegated to other PES people, who become responsible for the assigned operations.

The possibility of delegation therefore arises: together with the assignment of duties, responsibility, or part of it, is transferred to the delegated person.

The change to note no. 5 is equally important: in the definition at point 3.2.1 (URI): the unit may be the owner, the user or a designated person who normally prepares maintenance planning. Some duties may be assigned to others where necessary.

Some minor changes concern the work supervisor, PL, and the URL, at least in the definition:

The work-preparation function has been added and the possibility for URL to coincide with PL has been removed.

Point 3.2.3: Unit (or person) entrusted with preparing and carrying out the work. Responsibility remains, in practice, with the head of the unit.

It is stated that the installation-responsible unit is entrusted with preparing and carrying out the work, while the work supervisor is responsible for carrying it out.

ANNEX H:

This is a simple diagram that clearly explains the different areas of responsibility of RI, PL and URI:

“the installation-responsible unit is responsible during normal operation; the RI is responsible during the performance of the work.”

Having clarified these points concerning the professional roles introduced by the CEI 11-27 standard, it is useful and important to provide further information about traceability and digital communications.

6. Delegation and traceability

One of the most significant innovations in the fifth edition is the possibility of delegating the RI’s duties to PES people (Expert Persons). It is essential that this delegation be traceable, ensuring that responsibility, or part of it, is effectively transferred to the delegate. This is particularly important when the RI has to manage safety across several sites at the same time.

7. Digital communications

The new edition of the CEI 11-27 standards recognises the importance of digital technologies. Official communications may now take place through digital systems, provided that they ensure traceability and effectiveness. This includes completing the work plan, handing over and returning the installation, drafting procedures and delegations. This change represents an important step towards more efficient and modern management of electrical work.

8. How can Mela help with the digital management of information?

Mela’s app, with its ability to digitise and centralise information, can play a crucial role in supporting these new standards, making the management of electrical work faster, safer and smarter. The new standards not only respond to current needs but also pave the way for even safer and more coordinated management of electrical work in the future.

If you would like to find out more about how Mela works, a construction-site digitisation app, I invite you to try it free and see immediately how much your work can be optimised through new technologies.

9. Conclusion

The CEI 11-27 standard is a fundamental pillar of safety when working on electrical systems, clearly setting out the responsibilities and requirements of the roles involved. The fifth edition introduced important updates that further improve the effectiveness of management and safety during operations on electrical systems. It is essential for businesses and professionals in the sector to understand and correctly apply these standards in order to ensure a safe working environment compliant with applicable laws.

FAQ: Questions and answers about the CEI 11-27 standard

1. What are the main professional roles identified by the CEI 11-27 standard?

The CEI 11-27 standard identifies several key professional roles for managing and carrying out work on electrical systems. The main ones are:

  • PES (Expert Person): Has advanced technical and theoretical skills for analysing and assessing electrical risks. May carry out dead work and work near live parts.
  • PAV (Informed Person): Is informed about electrical risks and may work under the supervision of a PES.
  • PEI (Qualified Person): Is qualified to carry out electrical work on live systems.
  • URI (Installation-Responsible Unit): Overall responsibility for the installation and its safe operation.
  • RI (Installation Manager during work): Responsible for installation safety during electrical work.
  • URL (Work-Responsible Unit): Responsible for carrying out the electrical work.
  • PL (Work Supervisor): Coordinates the work operationally, ensuring that it is carried out safely.

2. What are the main changes introduced by the fifth edition of the CEI 11-27 standard?

The fifth edition of the CEI 11-27 standard, published in 2021, introduced several changes, including:

  • Updated definitions: Changes to the definitions of RI, URL and PL for greater clarity.
  • Clarifications concerning electrical work: Updates relating to functional checks and work organisation.
  • Exclusions concerning live working: New specific exclusions for live work.
  • Addition of Annex H: An explanatory diagram clarifying the responsibilities of the different people involved in electrical work.

3. Who is responsible for appointing PES, PAV and PEI roles?

The appointment of PES, PAV and PEI roles is the responsibility of the Employer. The appointment must be made in writing and must take each worker’s requirements into account. Appointing PES and PAV requires verification of the candidate’s technical skills, work experience and personal characteristics. For PEI, in addition to the PES and PAV requirements, physical and psychological fitness and specific training must be assessed.

4. How is training for PES, PAV and PEI managed under the CEI 11-27 standard?

  • Level 1A: Basic theoretical knowledge.
  • Level 1B: Operational knowledge and practical skills.
  • Level 2A: Theory of live working.
  • Level 2B: Practical live working. PES and PAV must acquire levels 1A and 1B, while PEI must master all four levels. Training may take place in a classroom or online and must be updated every 5 years with a refresher course of 4 hours.